Shortening The Shoot Bolts; Preparation For Mounting; Installing The Passive Leaf Lock - Assa Abloy OneSystem Série Notice De Montage

Serrure à crémone
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

A
± 1
m m
A
Installation

Shortening the shoot bolts

1
Cut the bolts to the calculated length using a hacksaw
(tolerance: ± 1 mm).
2
Remove sharp edges on the cut edge with some sandpaper or a fine metal file.
 The shoot bolts are the appropriate lengths and may be installed.
Attention!
Impaired function when the tolerance is exceeded or undercut: The lock can-
not function properly if the bolt rod is too short or too long. Observe the exact
calculated dimensions and tolerances when cutting to length.

Preparation for mounting

1
Place the door horizontally on an (ideally hip-high) assembly surface.
2
Cut two synthetic wires for the upper and lower bolt rods to a length that is
twice the rod length plus approx. 30 cm.

Installing the passive leaf lock

1
Follow the ASSA ABLOY Easy-Installation steps (Fig. 7 to Fig. 22, starting on
page 84).
2
Test all functions of the passive leaf lock and the door. Make sure that the
appropriate rebate gap is adjusted (Fig. 3). The lock must operate consistently
smoothly for all functions. An inconsistent or sluggish movement of the bolt
can indicate a mounting error or distorted installation of the lock.
 The lock is ready for use.