2.11 FAULT MESSAGES

Low battery: 12V supply to heating system has dropped below 10.8V, possibly causing system brownout.
This message clears automatically when the current reaches 11V. If the voltage decreases, various error messages can
also appear. These are not actual faults. Ensure that the boiler has the right voltage.
Fan restarts: Incorrect fan speed. New start attempt is made. Repeated faults result in "Fan failure". If "Fan failure"
recurs after resetting, contact a dealer. If "Fan restarts" is displayed, no action is necessary.
Gas failure: Out of gas or gas is not igniting. Check that the gas cylinder is full. Try a different gas cylinder, ensuring
it is propane gas. Check the gas regulator and that any isolation valves are open and not frozen. Ensure that gas is
available.
Overheat red fail: Overheat (red cable). Bleed the system of air. Check the fluid level in the expansion tank. It should
be approx. 0.5 in (1 cm) above the Min mark when cool. Check that the circulation pump is responding. Wait 15 min for
the fluid to cool down. This fault can arise if the heating system is run at high power at the same time as there are air
pockets in the heating system; the heating system should then be vented properly. If the fault recurs, contact a dealer.
Overheat blue fail: Overheat (blue cable).
Overheat PCB: Failsafe in the heating system has been triggered. Check the fluid level in the expansion tank. It
should be approx. 0.5 in (1 cm) above the Min mark when cool. Check that the heating system compartment is venti-
lated and that the vents are unobstructed. Do not stow items in the boiler compartment.
* Window open: Optional window sensor has been triggered; gas heating is suspended.
This message clears automatically and gas heating resumes when the window is closed.
Heater not found: Break in comms between the Alde control panel and boiler. Check the cable between the Alde
control panel and the boiler.
3rd party C. fail: Communication fault between Alde's panel and external panel.
Panel failure: Moisture is trapped in the control panel. Remove the Alde control panel from the vehicle and air it in a
warm, dry place overnight.
Red connection failure: Problem with the red cable or red contacts.
Yellow connection fail: Problem with the cable between the Alde panel and the CI master panel or its connectors.
To reset some of the faults and reboot, close the heating from the control panel and disconnect the 120V to the vehicle
and disconnect 12V from the boiler.
Functions marked with a (*) are accessories, which are not installed on all vehicles, refer to the vehicle manufacturer's