16. High altitude mode
The function only needs to be used if the
heating system will be powered by LP Gas at
altitudes above approx. 3,000 ft (1,000 m).
If the LP Gas burner runs unevenly at these
altitudes, turn off the heating (see section
2.1, Starting the heating system" on page
16) and then start the heating system in high
altitude mode.
When heating with LP Gas at high altitudes,
use propane to help obtain stable combustion.
17. Circulation pump
Pump settings: (Mode)
Cont.: The pump is in continius operation.
Therm: The pump is controlled by the room
sensor. This is the normal mode for heat and
hot water.
18. Starting the heating system automatically
This function is used to start the heating sys-
tem automatically at a later point in time.
With automatic start, the heating system
works for 24 hours and then stops. After that,
it repeats the automatic start once a week;
on the same day and time, as long as the
function is activated. For automatic start to
function, the On/Off button must be set to
Off.
19. Sound
Provides audible alerts in different situations:
• Button sound On and Off,
• Audible signal when hot water tem-
perature is reached when Alde Flow* is
installed and more hot water is selected
• Audible signal in the event of "Gas Fail-
ure".
20. Resetting the heating system
Use this function to reset the control panel to
factory settings. After resetting, the panel is
set as follows: the boiler is in Off mode, elec-
trical operation is in level 1, LP Gas heating
is in On mode and the indoor temperature is
72 °F/22 °C. Other functions are deactivated.
Functions marked with a (*) are accessories, which are not installed on all vehicles, refer to the vehicle manufacturer's
instructions.
21. External start
This function is used when starting the hea-
ting system from outside the vehicle. When
external start has been activated, the control
panel must be turned off. External start has
three modes, Off, Ext and 120V. In the Off
mode the function is turned off.
*Ext. This function is used when starting the
heating system through an external signal.
When the Ext. function has been activated,
the control panel must be turned off, but a
12V power source has to be connected. The
desired parameters/functions for the heating
system when it starts have to be set before
turning off the control panel.
This function requires installation of an acces-
sory for external starts.
120V. This function is used to start the
heating system when a 120V power source
is connected to the vehicle from outside.
When the 120V function has been activat-
ed, the control panel must be turned off but
a 12V power source has to be connected.
The desired parameters/functions for the heat-
ing when it starts have to be set before turning
off the control panel.(120V connected).
22. Language
This function is used to set the screen
language. The languages available are: En-
glish and Canadian French. However, the
service menu is only available in English
(see chapter 2.10).
23. Installed functions
The accessories that are installed are acti-
vated here (see chapter 2.12).
24. Service menu
The following readings are shown here:
Glycol temperature
Hot water temperature
12V power to the heating
To exit the Tool menu, press Return or
Menu.
21