Wiring Of Digital Frequency Input / Digital Frequency Output - Lenze 9300 vector Instructions De Montage

Masquer les pouces Voir aussi pour 9300 vector:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.9

Wiring of digital frequency input / digital frequency output

Technical data
Field
Connection at drive controller
Pin assignment
Output frequency
Signal
Load capacity
Special features
Internal voltage source
(X10/4, X10/5)
Field
Connection at drive controller
Input frequency
Signal
Signal evaluation
Current consumption
Special features
EDKVF9383 DE/EN/FR 4.0
Wiring of digital frequency input / digital frequency output
Digital frequency output X10
Connector: female, 9−pole, Sub−D
Dependent on the selected basic configuration
0 ... 500 kHz
Two−track with inverse 5 V signals (RS422) and zero track
Max. 20 mA per channel
(up to 3 slave drives can be connected)
The "Enable" output signal at X10/8 switches to LOW if the drive
controller is not ready for operation (e.g. disconnected from mains). This
may trip SD3 monitoring on the slave drive.
DC 5 V / max. 50 mA
Total current at X9/4, X9/5 and X10/4, X10/5: max. 200 mA
Digital frequency input X9
Connector: male, 9−pole, Sub−D
TTL level: 0 ... 500 kHz
HTL level: 0 ... 200 kHz
Two−track with inverse signals and zero track
Two−track without inverse signals and zero track (only for HTL level)
Via code C0427
Max. 5 mA
With activated SD3 monitoring, TRIP or warning is tripped if the "Lamp
Control" input signal at X9/8 switches to LOW.
Due to this the drive controller may respond if the master drive is not
ready for operation.