With function "Safe torque off" active

(from hardware version 1x)
Safety instructions for the installation of the "Safe torque off" function
The installation and commissioning of the Safe torque off" function must be
ƒ
carried out by skilled personnel only.
All safety−relevant cables (e.g. control cable for the safety relay, feedback contact)
ƒ
outside the control cabinet must be protected, for instance by a cable duct. Short
circuits between the single cables must be ruled out!
Wiring of the safety relay K
ƒ
absolutely vital.
The electrical reference point for the coil of the safety relay K
ƒ
with the protective conductor system (DIN EN 60204−1 paragraph 9.4.3). Only this
measure guarantees that the operation is protected against earth faults.
EDKVF9383 DE/EN/FR 4.0
Electrical installation
With function "Safe torque off" active
with insulated wire end ferrules or rigid cables is
SR
l
Control terminals
must be connected
SR
5
97