Mechanical Installation; Drilling The Holes Into The Mounting Plate - Lenze 9300 vector Instructions De Montage

Masquer les pouces Voir aussi pour 9300 vector:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4

Mechanical installation

I
Tip!
ƒ
ƒ
4.1

Drilling the holes into the mounting plate

Assembly space
Left/right of other controllers
Left/right of a non−heat−conducting wall
Top/bottom
Comply with the clearances given to ensure a sufficient cooling of the controller. When
using an air lock, different clearances apply (see Mounting Instructions for the air lock).
b
d
Fig.4−1
a
550 mm
1. Mark the bore holes on the mounting plate according to the figure.
2. Drill the holes into the mounting plate.
EDKVF9383 DE/EN/FR 4.0
Drilling the holes into the mounting plate
Lenze recommends to install an air lock. The air lock serves to dissipate the
heated cooling air directly from the control cabinet.
– Order no. E93ZWL2
A drilling jig for marking the bore holes is available as dxf−file in the
Internet in the "Download" area under www.Lenze.de.
a
a1
a1
a2
a2
a3
a3
a2
a2
a1
a1
Bore holes in the mounting plate for fixing the controller
a1
450 mm
340 mm
l
Mechanical installation
Minimum clearance
30 mm
100 mm
200 mm
a2
a3
225 mm
93vec079
b
d
1005 mm
9 mm (24x)
77
4

Publicité

Table des Matières
loading

Table des Matières