Fig. 1
45
o
Fig. 3
Butt These
Two Faces
Step 2:
ATR Angle Splice (OTP)
1. Install ATRs and Spacers opposite of the Angle Bracket first.
2. Measure from the inside of the post and add 2" [51mm] to
the over all length.
3. Install ATRs and Spacers on the Angle side measuring from
the end of the Bracket Cup adding 2-1/2" [63.5mm] to the
overall length.
4. Once both ATRs are installed center Angle Splice over Angle
Bracket.
5. Secure Angle Splice on ATRs with a Rubber Mallet.
Note:
• ATR should overhang Post 1" [25.5mm] in each side.
PURE VIEW: Al
Fig. 2
Bracket Has
To Be Set At
This Setting
Fig. 4