1. Measure distance between brackets and cut ATR spacer to
length. The spacer can be 1/4" [6.5mm] shorter than the
distance between brackets.
2. If one of the screw holes was cut off during the sizing of the
ATR spacer, use a 5/8" [16mm] drill bit to add another hole
1" from the end of the ATR spacer.
3. Attach the ATR spacer using the provided self-drilling
screws with a 5/16" [8mm] nut driver.
4. All screw holes must have a screw installed.
Note:
• Flat ATR uses a full length ATR spacer.
• DO NOT REMOVE BACKING OF DOUBLE SIDED TAPE UNTIL
YOU ARE READY TO PERMANENTLY ATTACH THE ATR.
Fig. 1
Fig. 2
Step 2:
Flat ATR Line & End
• Reference OTP Round ATR Line & End instructions on page 19.
Step 3:
Flat ATR Corner
• Reference OTP Round ATR Corner instructions on page 20.
Step 4:
Flat ATR Splice
• Reference OTP Round ATR Splice instructions on page 21.