Fortress Building Products PURE VIEW Instructions D'installation page 27

Masquer les pouces Voir aussi pour PURE VIEW:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ANGLE BRACKET: BRACKET INSTALLATION
Step 1:
Mark Bracket Hole Locations
1. Mark the centerline of each post with a pencil.
2. Take measurements used in Fig. 1 and 2 to mark bottom
and top bracket hole locations onto posts.
Note:
• Installed panel heights include space between the deck
surface and underside of bottom rail. AL
[825.5mm] panels have a 3-1/2" [89mm] space. AL
40" [1,016mm] panels have a 2" [51mm] space.
Fig. 1
Pre-drill Dimensions: Pre-drilling with a 3/16"[4.5mm] drill bit is required
A*
32-1/2" [826mm] Panel
(1)
4-3/16" [106.5mm]
(2)
40" [1016mm] Panel
2-5/8" [66.5mm]
*Dimension A positions bottom edge of rail (1) 3-1/2" [89mm] and (2) 2" [51mm]
above deck surface.
*Dimension A is measured from the bottom surface of post base.
Fig. 2
B
Step 2:
Pre-drill Angle Brackets
Tip:
• It's important to double check dimensions to confirm
accuracy of bracket hole locations before drilling.
PURE VIEW: Al
Bracket Hole Locations
35-3/8" [898.5mm]
41-1/2" [1053mm]
A
C
HOME GLASS BALUSTER INSTALLATION
13
HOME 32.5"
13
B
1" [25.5mm]
1" [25.5mm]
A
HOME
13
C
27

Publicité

Table des Matières
loading