Overview Of Master Commands - Sensopart FT 50 C S1 Série Instructions De Service Et De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Mounting and
operating instructions
Possible parameter format:
7 bit data byte
D7
D6
D5
D4
0
Data byte bit [6..0]
12 bit data item:
Byte i
D7
D6
D5
D4
0
0
Data item bit [11..6]
12 bit data item with switching output recognition (Q1 in bit D6, byte i + 1) and data valid (DV in bit D6 byte i)
Byte i
D7
D6
D5
D4
0
DV
Data item bit [11..6]
8.4

Overview of master commands:

Command descrip-
Dec. Hex.: ASCII Remark
tion
Store configurations
83
permanently
Read software version
118
(SW)
Activate factory
87
setting
Change sensor's
76
address
Lock and unlock keys
86
Configure special
98
functions
Read colour channel
99
Read all of sensor's
63
configuration settings
Read colour vector
65
Transfer colour matrix
105
„Teach colour" and
88
„scan"
FT 50 C...S1 Colour sensor - GB - 068-13821 - 10.10.2011-04
D3
D2
D1
D0
D3
D2
D1
D0
D3
D2
D1
D0
53
S
With this command, parameter settings and data are stored
permanently in the sensor. They thus remain in the memory
even after the power supply has been turned off.
76
v
57
W
The sensor resets all configurations incl. sensor address to
the factory settings.
4C
L
Transfer new address to sensor.
56
V
The command immediately locks or unlocks the operating
keys. It is not necessary to connect PIN 8. It is only
possible to unlock the keys again by sending the appropri-
ate telegram command.
62
b
Configure N.O. / N.C. functions and drop-out delay time.
63
c
Up to 5 colours / colour ranges are stored in separate
colour channels within the sensor. Upon receipt of the
command, the sensor transfers information on the colour
channels which were detected in the last measuring cycle.
3F
?
The sensor transfers all configuration settings (parameters
and colour channels).
41
A
Read current measured colour value (colour vector).
(Sensor sends colour vector and the status of the switching
output in the last 12 bit data item).
69
i
The master programs the 5 colour channels.
58
X
Command for teach-in of colours and scanning of colour
ranges.The process consists of a command sequence
which must be executed.
Byte i + 1
D7
D6
D5
D4
0
0
Data item bit [5..0]
Byte i + 1
D7
D6
D5
D4
0
Q1
Data item bit [5..0]
D3
D2
D1
D0
D3
D2
D1
D0
Ex.
8.5.1
8.5.2
8.5.3
8.5.4
8.5.5
8.5.6
8.5.7
8.5.8
8.5.9
8.5.10
8.5.11
49

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ft 50 c-1-s1-l8Ft 50 c-2-s1-l8Ft 50 c-3-s1-l8

Table des Matières