Configuration Via The Control Panel; Quick User Guide (068-13883) See Fold-Out Page; Activate Configuration Mode (Conf); Menu „C": Teach A Single Colour - Sensopart FT 50 C S1 Série Instructions De Service Et De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Mounting and
operating instructions
Also via the electrical interface:
• It is possible to teach a reference colour via the external input cable
„IN ET"
• It is possible to scan a colour range via the external input cable
„IN ES"
• All sensor functions can be configured and read-out via the RS485
interface
• The individual colours / colour ranges can be evaluated individually via
the RS485 interface
Also via the RS485 interface:
• Sensor address
7.3

Configuration via the control panel

7.3.1

Quick user guide (068-13883) see fold-out page

7.3.2

Activate configuration mode (conf)

INFORMATION
= LED ON /
Activity
Picture follows Remark
SET
C S
> 3 s
until LED „C"
(yellow) flashes
7.3.3
Menu „C": Teach a single colour
INFORMATION
• When a colour is taught, all previously taught or scanned colours / colour ranges are deleted.
• Colour and intensity tolerance are set individually during the programming procedure.
• After the teaching process, the yellow LED „C" lights up when the switching output „Q" is
active a colour has been detected (when switching mode = N.O. = Factory setting is selected).
FT 50 C...S1 Colour sensor - GB - 068-13821 - 10.10.2011-04
= LED flashes /
= LED OFF
LED flashes when configuration mode is activated.
+/F
Once configuration mode has been activated, a time window of approx.
20 s opens. Should no further input occur during this period, then the sensor
switches back to operating mode.
Factory setting
-
-
-
-