Sensopart FT 50 C S1 Série Instructions De Service Et De Montage page 42

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Procedure:
Step
Menu item
Activity
1
Operating
Position object
mode (no
menu item)
2
Press
SET
> 3 s
until LED „C"
(yellow) flashes
3
Teach
Press
colours
4
Release
5
Press
several
times until
the required
tolerance is
selected
6
Confirm with
7
Press
several
times until
the required
tolerance is
selected
8
Confirm with
* when switching mode = N.O. = Factory setting is selected.
42
Picture follows Remark
C S
+/F
SET
C S
+/F
SET
C S
+/F
SET
C S
+/F
SET
Observe operating parameters such as scanning distance,
direction of movement, inclination etc. (see chapter 5
„Mounting").
LED „C" (yellow) flashes, when time lock is open and
configuration mode is activated.
Press button briefly and release it. When the button gets
released, the colour is taught.
Colour value is stored in sensor.
Sensor is ready for the setting of colour tolerance.
LED „C" (yellow) lights up when colour is detected,*
LEDs „Tol. C" (green) light up.
Select colour tolerance (colour selectivity).
1
2
C S
+/F
C S
+/F
1 = smallest tolerance, 4 = greatest tolerance
3 = factory setting
Colour tolerance is stored.
Sensor is ready for the setting of intensity tolerance.
LED „C" (yellow) lights up when colour is detected,*
LEDs „Tol.I" (red) light up.
Select intensity tolerance (grey selectivity).
1
2
C S
+/F
C S
+/F
1 = smallest tolerance, 4 = greatest tolerance
2 = factory setting
Sensor is ready for use.
LED „C" (yellow) lights up when colour is detected / swit-
ching output „Q" is active*.
FT 50 C...S1 Colour sensor - GB - 068-13821 - 10.10.2011-04
Mounting and
operating instructions
3
4
C S
+/F
C S
+/F
3
4
C S
+/F
C S
+/F

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ft 50 c-1-s1-l8Ft 50 c-2-s1-l8Ft 50 c-3-s1-l8

Table des Matières