Overview Of Master Commands - Sensopart FT 50 RLA-70-L8 Instructions De Service Et De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8.4

Overview of master commands:

Command description Dec.
Set switching output Q
Set switching output Q
Set Q
as output
2
„Good Target"
Set Q
as Trigger input
1
Set Q
as control input
1
for laser ON/OFF
Averaging
Scaling analogue
output (4 mA)
Scaling analogue
output (20 mA)
„Autom. zero" function
(with Q
as control
1
input)
Autom. centre" (with Q
as control input)
„Maximum Hold" func-
tion (with Q
as control
1
input)
Minimum Hold" function
(with Q
as control
1
input)
„Difference Hold" func-
tion (with Q
as control
1
input)
Activate factory setting
64
Hex.:
ASCII Remark
49
31
1
1
50
32
2
2
71
47
G
84
54
T
69
45
E
66
42
B
78
4E
N
72
48
H
90
5A
Z
67
43
C
1
88
58
X
77
4D
M
68
44
D
87
57
W
Switching output Q
is set:
1
1st and 2nd switch point
N.C / N.O.
Pulse stretching
Switching output Q
is set:
2
1st and 2nd switch point
N.C / N.O.
Pulse stretching
Q
switches when an object is in the measuring range
2
(Good Target).
Q
is set as trigger input. With rising edge on Q
1
measured value is held until the next trigger occurs.
Used to switch laser beam on and off.
Q
= +U
(laser beam ON),
1
B
Q
= -U
(laser beam OFF).
1
B
Last measured value remains. When reactivated, the
response time is prolonged according to the set mean
value.
The number of meas. values used for averaging
(arithmetic mean) is set (1 / 10 / 100 meas. values).
The transmitted value is set as 4 mA point at analo-
gue output.
The transmitted value is set as 20 mA point at analo-
gue output.
The output characteristics 4 – 20 mA are displaced.
If Q
= +U
the current measured value is set as the
1
B
analogue value 4 mA. The incline of the characteri-
stics is maintained. The max. value of the characteri-
stics is limited by the measuring range.
The output characteristics 4 – 20 mA are displaced.
If Q
= +U
the current measured value is set as the
1
B
analogue value 12 mA. The incline of the characte-
ristics is maintained. The min. or max. value of the
characteristics are limited by the measuring range.
Provided Q
= +U
, the max. recorded measured
1
B
value is stored. If Q
= -U
1
transmitted at the analogue output or can be called up
via „Measured operating values".
Provided Q
= +U
, the min. recorded measured
1
B
value is stored. If Q
= -U
1
transmitted at the analogue output or can be called up
via „Measured operating values".
Provided Q
= +UB, the difference between the mea-
1
sured values is saved. If Q
value is transmitted at the analogue output or can be
called up via „Measured operating values".
The sensor resets all settings to the factory setting
incl. sensor address.
FT 50 RLA Disctance sensor - GB - 068-13671 - 20.04.2009-05
Mounting and
operating instructions
,
1
, the determined value is
B
, the determined value is
B
= -U
, the determined
1
B
Example
8.5.1
8.5.2
8.5.3
8.5.4
8.5.5
8.5.6
8.5.7
8.5.8
8.5.9
8.5.10
8.5.11
8.5.12
8.5.13
8.5.14

Publicité

Table des Matières
loading

Table des Matières