Mounting and
operating instructions
Example telegram
(in the example, the sensor has the address 1)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Check sum
8.5.20

Fast measured value output

Command (Byte 3): decimal 70; hexadecimal 0x46
Parameter:
no
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
Example telegram
(in the example, the sensor has the address 1)
Master telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Command
4. Byte
Check sum
If output Q
is set to high after this command, the continuous transmission of measured values begins according
1
parameter format data 4. No intervention is possible via the software during this time.
INFORMATION
This command must not be used in bus mode.
8.5.21

Change the sensor's address

Command (Byte 3): decimal 76; hexadecimal 0x4C
Parameter:
New address
Reply (Byte 3):
decimal 89; hexadecimal 0x59
Parameter:
no
Change in the address of the connected sensor.
FT 50 RLA Disctance sensor - GB - 068-13671 - 20.04.2009-05
Decimal
Hex.:
129
81
4
04
73
49
76
4C
Decimal
Hex.:
129
81
4
04
70
46
67
43
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Data
5. Byte
6. Byte
Check sum
Sensor's reply telegram
Designation
1. Byte
Address
2. Byte
Length
3. Byte
Reply
4. Byte
Check sum
Parameter format
7 bit data byte
Decimal
Hex.:
129
81
6
06
89
59
0
00
0
00
94
5E
Decimal
Hex.:
129
81
4
04
89
59
92
5C
to
75