Beurer BC 85 Mode D'emploi page 19

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
a doctor before using the blood pressure monitor during
pregnancy.
• In the case of restricted circulation on the arm as a result of
chronic or acute vascular diseases (including vascular con-
striction), the accuracy of the wrist measurement is limited.
In this case you should avoid using an upper arm blood
pressure monitor.
• This device is not intended for use by people (including chil-
dren) with restricted physical, sensory or mental skills or a
lack of experience and/or a lack of knowledge, unless they
are supervised by a person who has responsibility for their
safety or they receive instructions from this person on how
to use the device. Supervise children around the device to
ensure they do not play with it.
• Cardiovascular diseases may lead to incorrect measure-
ments or have a detrimental effect on measurement ac-
curacy. The same also applies to very low blood pressure,
diabetes, circulatory disorders and arrhythmias as well as
chills or shaking.
• The blood pressure monitor must not be used in connection
with a high-frequency surgical unit.
• Only use the unit on people who have the specified wrist
measurement for the device.
• Please note that when inflating, the functions of the limb in
question may be impaired.
• During the blood pressure measurement, the blood circula-
tion must not be stopped for an unnecessarily long time. If
the device malfunctions, remove the cuff from the arm.
• Do not allow sustained pressure in the cuff or frequent
measurements. The resulting restriction of the blood flow
may cause injury.
• Ensure that the cuff is not placed on an arm in which the ar-
teries or veins are undergoing medical treatment, e.g. intra-
vascular access or therapy, or an arteriovenous (AV) shunt.
• Do not use the cuff on people who have undergone a mas-
tectomy.
• Do not place the cuff over wounds as this may cause further
injury.
• Place the cuff on your wrist only. Do not place the cuff on
other parts of the body.
• The blood pressure monitor can only be operated with bat-
teries.
• To conserve the batteries, the monitor switches off auto-
matically if you do not press any buttons for 2 minutes.
• The device is only intended for the purpose described in
these instructions for use. The manufacturer is not liable for
damage resulting from improper or careless use.
Instructions for storage and maintenance
• The blood pressure monitor is made from precision and
electronic components. The accuracy of the measurements
and service life of the device depend on its careful handling:
– Protect the device from impacts, humidity, dirt, marked
temperature fluctuations and direct sunlight.
– Do not drop the device.
– Do not use the device in the vicinity of strong electromag-
netic fields and keep it away from radio systems or mobile
telephones.
19

Publicité

Table des Matières
loading

Table des Matières