A.16 Mbdde.ini - Siemens SINUMERIK 840Di sl Manuel De Mise En Service

Masquer les pouces Voir aussi pour SINUMERIK 840Di sl:
Table des Matières

Publicité

A.16
MBDDE.INI
Vue d'ensemble
Le fichier MBDDE.INI est exploité au démarrage. Les paramètres des alarmes et du fichier
journal courant dans le répertoire \mmc2 sont réglés.
[Alarme]
; determines the order in which the alarms are inserted in the alarm
list
; possible values:
; FIRST: makes newer alarms stand on top of the list
; LAST: inserts the newest alarm at the bottom
ORDER=LAST
; the alarm/message line is able to scroll the occurred alarms
; possible values:
; 0 or negative value: no scrolling
; 500 - 32767: interval in ms
RotationCycle=0
; determines if the alarm server should connect to ALARM_S/SQ or not
; possible values:
; 0 Alarm_S/SQ not handled
; 1 Alarm_S/SQ handled (default)
Alarm_S=1
; if Alarm_S/SQ handling is enabled this key determines if Quits
should
; be entered into the alarm-protocol
; possible values:
; 0 Alarm_SQ quits are not entered into the alarm protocol
;(backcompatible)
; 1 Alarm_SQ quits are entered into the alarm protocol (default)
Protocol_Alarm_SQ=1
; If Alarm_S/SQ handling is enabled this key determines if the
; workaround regarding an error in the firmware of the PLC is
; active or not. This workaround corrects the listing of
; Alarm_S/SQ in the diagnosis but causes multiple entries in
; the protocol listing of one alarm event (NEW, NULL, QUIT).
; Using a newer PLC firmware (PLC Besy Stand: S7 PLC_315 2DP
; 2AF03 12.30.03 or higher only neccessary at NCU57x.1) this
; workaround can be set inactive to correct protocol writing.
;
; Attention: Setting the workaround inactive while using an PLC
; firmware elder than 12.30.03 leads to unpredictable results!
;
; possible values:
; 0 Workaround active
; 1 Workaround inactive (default)
HMI-Advanced (IM4)
Manuel de mise en service, 03/2009, 6FC5397-0DP10-3DA0
Liste des fichiers INI

A.16 MBDDE.INI

305

Publicité

Table des Matières
loading

Table des Matières