Thank you for buying this product, our company is sure that you will be more than satisfied with the performance of the product.
Read the Instruction Manual supplied with this product carefully, as it provides important information about safety, installation, operation and
maintenance. This product complies with recognised technical standards and safety regulations. We declare that this product is in conformity with the
following European Directives: 89/336/EEC (amended by RL 91/263/EEC, 92/31/EEC and 93/68/EEC), 73/23/EEC, 99/5/EEC.

1) GENERAL OUTLINE

Capri is a control unit especially designed for tubular motors controlling roller shutters and sunblinds and is compatible with the EElink protocol.
The unit controls one tubular motor and is pre-arranged for the connection of additional attachments such as anemometers, twilight sensors, opening/
closing and stop push-buttons. Furthermore, it is possible to connect special safety devices when necessary. The commands can also be sent by radio
by means of a transmitter of the rolling code series. Memorization on the transmitters is obtained based on the self-learning method. The unit provides
a centralized wire control system that can be subdivided into 8 or more zones regardless of the wiring.
2) USE OF WIRE CONTROLS
The push-buttons and/or switches for the wire control are provided with an indication of the operation direction. It is necessary to check it before using
the set (fig.1). Remember that, in case of centralized control or control sensors (anemometers, twilight sensors, timers), the actuators might start
accidentally. Keep children away from the set or its components.
3) USE OF RADIO CONTROLS
The radio-controls, which can be used with the CAPRI control board, can feature 1, 2 or 4 keys. The functions of each key are the following:
Key 1: local control with 4-step logic (the first impulse opens, the second impulse stops on opening, the third impulse closes, the fourth stops on closing).
Key 2: local and zone stop control.
Key 3: local and zone opening control.
Key 4: local and zone closing control.
For the identification of the keys, refer to fig.2. Remember that, in case of centralized control or control sensors (anemometers, twilight sensors, timers),
the actuators might start accidentally.
Keep children away from the set or its components. Never open the transmitters, short-circuit or recharge the batteries.

4) MAINTENANCE AND DEMOLITION

The maintenance of the system should only be carried out by qualified personnel regularly.
In the event of faults, avoid any attempt to personally carry out repairs. Section the power supply line and request the assistance of qualified personnel.
The materials making up the set and its packing must be disposed of according to the regulations in force.
Batteries must be properly disposed of.
T1
Led
T2
P1
65
USER'S MANUAL
1 2 .
5
T1
8
3 4 .
T2
T3
T4
1 6
Fig. 1
Fig. 2
Led
P1
ENGLISH
44
18,5
TO4
82