General Safety; General Outline; Technical Specifications - BFT ROLLING-CODE RTD Instructions D'utilisation Et D'installation

Radio commande programmable
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
ENGLISH
Thank you for buying this product, our company is sure that you will be
more than satisfied with the product's performance. The product is
supplied with a "Warnings" leaflet and an "Instruction booklet".
These should both be read carefully as they provide important
information about safety, installation, operation and maintenance.
This product complies with the recognised technical standards and
safety regulations. We declare that this product is in conformity with
the following European Directives: 89/336/EEC and 73/23/EEC (and
subsequent amendments).

GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with
this product should be read carefully as they provide important
information about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc)
according to the provisions set out by current standards. Keep
nylon or polystyrene bags out of children's reach.
Keep the instructions together with the technical brochure for
future reference.
This product was exclusively designed and manufactured for the
use specified in the present documentation. Any other use not
specified in this documentation could damage the product and be
dangerous.
The Company declines all responsibility for any consequences
resulting from improper use of the product, or use which is
different from that expected and specified in the present
documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the
following European Directives:It complies with the 89/336/EEC,
1999/5/CEE, European Directive and subsequent amendments.
As for all non-EEC countries, the above-mentioned standards as
well as the current national standards should be respected in
order to achieve a good safety level.
The Company declines all responsibility for any consequences
resulting from failure to observe Good Technical Practice when
constructing closing structures (door, gates etc.), as well as from
any deformation which might occur during use.
The installation must comply with the provisions set out by the
following European Directives:It complies with the 89/336/EEC,
1999/5/CEE, European Directive and subsequent amendments.
Disconnect the electrical power supply before carrying out any
work on the installation. Also disconnect any buffer batteries, if
fitted.
Fit an omnipolar or magnetothermal switch on the mains power
supply, having a contact opening distance equal to or greater than
3mm.
Check that a differential switch with a 0.03A threshold is fitted just
before the power supply mains.
Check that earthing is carried out correctly: connect all metal parts
for closure (doors, gates etc.) and all system components provided
with an earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are
needed to protect the area from any danger caused by squashing,
conveying and shearing.
Position at least one luminous signal indication device (blinker)
where it can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the
automation safety and correct operation when other manufacturers'
components are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly
authorised by the company.
Instruct the product user about the control systems provided and
the manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation
operation area.
Keep radio control or other control devices out of children's reach,
in order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the
automation system, and always request the assistance of qualified
12 - RTD- Ver. 03
INSTALLATION MANUAL
www.BFTGateOpeners.com | (800) 878-7829
personnel.
Anything which is not expressly provided for in the present
instructions, is not allowed.

1) GENERAL OUTLINE

Programmable self-learning radio receiver system, having the following
main features:
Receiver which can be cloned with 512 or 2048 codes
Up to 4 outputs (1 standard + 3 modular) with automatic recognition
of the modules entered
Outputs which can be configured as monostable, bistable, timed,
anti-aggression
Programming by means of incorporated display
Operation with fixed and variable codes
Compatible with EElink protocol for fast installation and
maintenance
Group function for automatic entry of groups of transmitters
Protection of receiver by means of password.
The RTD receiver combines the characteristics of utmost safety in
copying variable code (rolling code) coding with the convenience of
carrying out transmitter "cloning" operations thanks to an exclusive
system.
Cloning a transmitter means creating a transmitter which can be
included automatically within the list of the transmitters memorised in
the receiver, either as an addition or as a replacement of a particular
transmitter.
Therefore it will be possible to remotely program a large number of
additional transmitters, or for example, replacement transmitters for
those which have been lost, without making changes directly to the
receiver.
Replacement cloning is used to create a new transmitter which takes
the place of the one previously memorised in the receiver; in this way
the lost transmitter can be removed from the memory and no longer be
usable.
When coding safety is not a decisive factor, the RTD receiver allows
you to carry out fixed code additional cloning, which although
abandoning the variable code, provides a high number of coding
combinations, while maintaining the option of "copying" any receiver
already programmed.
Using clones when there is more than one receiver (as in the case of
communal buildings),
and especially when a distinction is to be made between clones to be
added to or replaced in individual or collective receivers, could turn out
to be rather difficult. The RTD receiver cloning system for communal
buildings makes it particularly easy to solve the problem of clone
storage for up to 250 individual receivers.
Passageway control is managed by an output with a N.O. contact;
when needed, the number of outputs can be increased by means of
appropriate MOP optional modules to obtain a maximum of 4 output
channels, which can be configured independently.

2) TECHNICAL SPECIFICATIONS

2.1) Receiver
Power supply: .................................................. 230V
Frequency: ....................................................................... 433.92MHz
Working temperature: .................................................... -20 to +55°C
Coded by means of: ....................................... Rolling-code algorithm
No. combinations: ................................................................ 4 milliard
Antenna impedance: ................................................. 50 Ohm (RG58)
Dimensions: .......................................................................... see fig. 1
Relay contact: ................................................................... 0,5A, 12V=
Degree of protection: ................................................................ IP 20*
Max no. radio transmitters to be memorised:
Receiver version
No. radio transmitters
RTD 512
512
RTD 2048
2048
(*) The degree of protection of the container becomes IP55 with the
use of an accessory supplied on request. Only use fittings suitable for
the container dimensions and cable diameter.
±10%50Hz (*)