Thank you for buying this product, our company is sure that you will be more than satisfied with the product's performance. The product is supplied with
a "WARNINGS" leaflet and an "INSTRUCTION MANUAL".
These should both be read carefully as they provide important information about safety, installation, operation and maintenance. This product complies
with the recognised technical standards and safety regulations. We declare that this product is in conformity with the following Directives: CAN/CSA-C22.2
No. 247-92 UL Std. No. 325

1) GENERAL OUTLINE

The ARIES control unit has been designed for swing gates. It can be used for one or two gate controllers.

2) FUNCTIONS

STOP: In all cases: it stops the gate until a new start command is given.
PHOT: Functions can be set with Dip-Switch.
Activated during closing.
Activated during opening and closing.
Rapid closing
ON: When the position of the gate photocells is exceeded, during both opening and closing, the gate automatically starts to close even if TCA is
activated. We recommend setting DIP3 to ON (photocells only activated during closing).
Blocks impulses
ON: During opening, START commands are not accepted.
OFF: During opening, START commands are accepted.
Photocells
ON: Photocells only activated during closing.
OFF: Photocells activated during opening and closing.
Automatic closing time (TCA)
ON: Automatic closing activated (can be adjusted from 0 to 90s)
FOR THE INSTALLER: check the boxes you are interested in.
Gate closed
During opening
Gate open
During closing
After stop

3) MAINTENANCE AND DEMOLITION

The maintenance of the system should only be carried out by qualified personnel regularly. The materials making up the set and its packing must
be disposed of according to the regulations in force.
Batteries must be properly disposed of.
WARNINGS
Correct controller operation is only ensured when the data contained in the present manual are observed. The company is not to be held
responsible for any damage resulting from failure to observe the installation standards and the instructions contained in the present
manual.
The descriptions and illustrations contained in the present manual are not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial improvement of the product, while leaving the essential product features
unchanged, at any time and without undertaking to update the present publication.
4 -
ARIES UL - Ver. 03
USER'S MANUAL
START: four-step logic
it opens
it stops and activates TCA
it closes
it stops and does not activate TCA
it starts opening
START: two-step logic
it opens
it stops and activats TCA (if activated)
it closes
it opens
it opens
SCA: Gate open indicating light
off
on
on
flashing