Télécharger Imprimer la page

Keysight Technologies U2701A Guide D'utilisation page 126

Publicité

Trigger Settings
The oscilloscope provides three trigger modes: edge, pulse, and TV. Pulse width
trigger is used to find pulses with certain pulse widths. TV is used to trigger on
fields or lines for standard video waveforms.
Edge Trigger
Edge trigger can be used with analog and digital circuits. An edge trigger occurs
when the trigger input passes through a specified voltage level with the specified
slope.
Table 2-2
Edge Trigger menu
Edge Trigger Panel Controls
Menu
Settings
Trigger
Auto
Mode
Normal
Source
Channel 1
Channel 2
External
Settings
Level
Holdoff
Trigger Settings
Rising
Falling
Alternate
Either
Coupling
DC
AC
LF-Reject
HF-Reject
Keysight U2701A/U2702A User's Guide
Comments
Able to acquire waveform even when no trigger occurs
Acquires waveform only when trigger occurs
Sets Channel 1 as the trigger source
Sets Channel 2 as the trigger source
Sets External as the trigger source
Sets the voltage point on the waveform where trigger occurs
Sets the waiting period before starting a new trigger
Trigger on rising edge
Trigger on falling edge
Trigger on alternate edge
Trigger on either edge
Sets the input coupling to DC
Sets the input coupling to AC
Sets the input coupling to low frequency reject
Sets the input coupling to high frequency reject