Télécharger Imprimer la page

LORCH MicorTIG 200 DC ControlPro Manuel D'utilisation page 54

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 178
Technical data
Greatest effective mains current
Input power S
(100%/40°C)
1
Input power S
(60%/40°C)
1
Input power S
(max. current)
1
Efficiency η at 100% ED
Efficiency η at I
max
2
Weldable electrodes
Mains
Mains voltage (50/60 Hz) 1~
Mains frequency
Positive mains tolerance
Negative mains tolerance
Mains connection cable
Mains plug
Current consumption I
Mains fuse
Power factor (for I2
max.
Power factor λ (at I
max)
2
Max. permitted network impedance Zmax
according to IEC 61000-3-11/-12
Recommended generator performance
Machine
Protection class (EN 60529)
Insulation class
Cooling method
Noise emission
Dimensions and weights
Dimensions (LxWxH)
Weight with mains cable
Tab. 8:
Technical data
- 52 -
1 no-load
)
MicorTIG 200 DC
Units
I
/A
1eff
kVA
kVA
kVA
%
%
mm
V
Hz
%
%
mm²
A
A/tr
cos φ
kVA
IP
dB(A)
mm
kg
ED = Switch-on duration
909.4169.9-03
Technical data
MicorTIG 200 DC
(115 V)
23.7
2.7
3.2
4.5
82
80
1.5 - 3.2
115
50 - 60
15
15
3 x 2.5
Isolated ground
open
0.2
25
0,99
0,99
530
8
23S
F
F
<70
360 x 130 x 215
6,8
(230 V)
15.1
3.5
4.2
5.7
86
85
1.5 - 4.0
230
15
15
socket
0.3
16
0,99
0,99
851
8
23S
6,8
04.19

Publicité

loading