Technical Characteristics - DITEC Sector Reset Manuel D'installation, D'entretien Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

17
15
5
18
10
11
Ref. Description
1
Transom
2
Motor K10
3
Transmission chain
4
Rolling shaft
5
Manual release lever
6
Polyzene guide upper section
7
Polyzene guide lower section
8
Fixing plate of the guide
9
Linear Encoder (SLE)
10
Supporting spring
11
Fixing screw
12
Belt counterweight

2. TECHNICAL CHARACTERISTICS

CONTROL PANEL TRIPHASE (49E)
Power supply voltage ............400 V triphase 50/60 Hz
Line sizing ............................................................... 5 A
Auxiliary control power voltage ........................24V
Motor rating ..................................................... 0,9 KW
Control board protection class ............................ IP 55
Operating temperature .............................. - 5 + 50 °C
Correctly size the line conductor cross-section by referring to the indicated absorption and taking the length and
installation of the cables into account.
2
3
8
9
6
7
1
23
21
22
20
Ref. Description
13
Modular counterweight
14
Right column cover
15
Left column cover
16
Right column
17
Left column
18
Electronic board
19
Photocell 5FB
20
Polyester curtain
21
PVC transparent window
22
Vertical re reinforcing strips
23
Bottom edge with sand ballast
CONTROL PANEL INVERTER (52E)
Power supply voltage ........ 230 V monofase 50/60 Hz
Line sizing ............................................................. 12 A
Auxiliary control power voltage ........................24V
Motor rating ..................................................... 0,9 KW
Control board protection class ............................ IP 55
Operating temperature .............................. - 5 + 50 °C
- 31 -
EN
12
4
13
16
14
19
0DT848 01-12-2021

Publicité

Table des Matières
loading

Table des Matières