Timed Opening Menu - DITEC Sector Reset Manuel D'installation, D'entretien Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

STEP 1
level options
st
12
Closing speed
in (Hz)
13
Enable service alarms
14
Service thresh
15
Enable stop 1-2
16
Brake resistance
(default NO)
17
PARAMETER RESET
ONCE PROGRAMMING HAS ENDED, SET DIP2 TO OFF

6.3 Timed opening menu

With door in STOP position and DIP 8 ON you enter the menu CYCLIC MODE. By activating this mode it is possible to set
a timed opening at regular time intervals. Once the mode is set put DIP 8 OFF.
STEP 1
level options
st
1
CYCLIC MODE
2
TIME UNIT
3
OPENING TIME
4
AUTO CLOS.TIME
5
TOT
6
RESET CYCLES
When CYCLIC MODE is active, the display shows every 2 sec:
TOT cycle - count down to next open/OPENING TIME
0DT848 01-12-2021
Scrolling
Confirm
Scrolling
Confirm
2
level options
nd
CHANGE VALUE
YES
NO
RESET?
CHANGE VALUE
YES
NO
YES
NO
CONFIRM
2
level options
nd
TIMER OFF
TIMER ON
MIN.
SEC.
1 ...200
1....200
VALUE
RESET?
- 44 -
Notes
The setting of higher values
must be assessed according to
door dimensions and operating
conditions.
Restart the service count down
Option available only if YES has
been selected for point 14).
Set value to steps of 1000 cycles
Max 200,000 cycles
If set to YES, opening of the
contact 1-2 STOPS the door.
Set to YES when the door is
supplied with brake resistance.
Confirm to go back to the
installation menu.
Notes
Timer not active
Timer active
Timer by minuts
Timer by seconds
Set the regular time intervals
Set the time during which the door
remains open
Cycle counter
Cycle counter reset