Electronic Control Panel 5.1 49E - Connections - DITEC Sector Reset Manuel D'installation, D'entretien Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.1 49E ELECTRONIC CONTROL PANEL - CONNECTIONS
49E
Command
1
2
N.O Automatic closing
N.O Opening
1
3
1
4
N.O Closing
N.C Reversal safety
1
6
41
8
N.C Reversal safety
1
9
N.C Stop
1
9
N.O Non-pulse command Permanently opening the safety contact enables the operation by non-
N.O Partial opening
1
20
0
11
N.C Closure limit switch
N.C Opening limit switch
0
12
N.O limit switch photocell By-pass photocell
0
17
Operation by non-pulse command
17 14 12 1 1 0 0 0
Output
1
+
0
0
14
- LK +
U W V
M
3 ~
0DT848 01-12-2021
Function
Permanently closing the contact enables automatic closing.
With DIP1=ON the closure of the contact activates an opening operation.
Step-by-step
With DIP1=OFF the closure of the contact activates an opening or closing
operation in the following sequence: open-stop-close-open.
Note: if automatic closing is enabled, the stop is not permanent but at a
time that is set by the TC.
The closing manoeuvre starts when the contact is closed.
Opening the safety contact triggers a reversal of the movement (reopening)
device
during a closing operation.
Opening the safety contact triggers a reversal of the movement (reopening)
device
during a closing operation.
Opening the safety contact stops the current operation.
pulse command.
In this state, the opening (1-3/1-20) and closing (1-4) controls function only
if held in the pressed position, and the automation stops when the controls
are released.
All safety switches, the step-by-step control and the automatic closing
function are disabled.
The closing of the contact activates a partial opening operation of the
duration set with the RP trimmer.
Once the automation stops, the partial opening control performs the
opposite operation to the one performed before stoppage.
The opening of the limit switch contact stops the closure operation.
The opening of the limit switch contact stops the opening operation.
1 1
2 3 4 6 8
9
Value
Accessories power supply.
24 V = / 0,5 A
Power supply output for external accessories, including automation status
lamp.
Lampeggiante (FML).
24 V = / 50 W
Flashing signal (jumper OFF on FML).
(2 A)
Activated during opening and closing operations.
24 V = / 0,5 A
Output activated during the door running.
Three-phase motor.
400 V~ / 4 A
Note: if the direction of rotation of the motor is incorrect for the desired direction
of movement, swap the U - W phases.
INPUTS
Operation by pulse command
20 41
1 7 14 12 1 1 0 0 0
OUTPUTS
- 34 -
Description
1 1
2 3 4 6 8
9
20 41
Description