Connection Terminals; Mechanical Mounting; Electrical Connection; Prerequisites - ASO Safety Solutions ELMON rail 32-332 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety Relais
V1.0: If no error is present, then LED Power shows the function control (briefly off).
V2.1 and later: If no error is present, then LED Power shows the operating state (on).
During the output of an error message, the number of output pulses indicates the error:
Pulse
Error message
1
Voltage supply outside of the valid value range
2
INDUS transmission error
3
Output control Open faulty
4
Output control Close faulty
5
Data transmission between microcontrollers faulty
6
Testing sensor input faulty ( stationary contact edges) (Open/Close)

6.3 Connection terminals

STOP Opening
STOP Closing
STATIONARY Opening
STATIONARY Closing
Transmit
24 V AC/DC
L1 N

7. Mechanical mounting

The switching unit is to be professionally mounted at a suitable location. After removing the cover, the housing
can be mounted with four screws.
Do not install the switching unit in the immediate vicinity of strong sources of heat.
The switching unit may be mounted in any orientation. To prevent moisture penetration, it should, however,
be installed so that the cable conduits point downward.

8. Electrical connection

8.1 Prerequisites

The signal cable must not be placed parallel to the motor cable or other power cables.
Cables installed outdoors or outside of the switching cabinet must be protected appropriately.
The protection class specified for this device is only ensured if the supply lines have been properly clamped
to the screw connections.
Connecting to the wrong terminals can destroy the switching unit.
The limit values for the supply voltage and the switching capacity of the relay specified in the „technical
specifications" are to be observed.
16
Control circuit (emergency-off)
Stop, direction of movement - Opening (channel 1)
Control circuit (emergency-off)
Stop, direction of movement - Closing (channel 2)
Sensor input
Direction of movement - Opening (channel 1)
Sensor input
Direction of movement - Closing (channel 2)
No assignment
Supply voltage 24 V AC/DC
Supply voltage 230 V 50/60 Hz