Descaling with the BEEM Premium Descaler Concentrate
1. Fill the water reservoir (6) up to the MAX marking with a concentrate/water solution of
no more than 1:20 (one part concentrate to 20 parts water).
2. Move the On / Off switch (12) on the side of the water reservoir to the I (On) position to
switch on the device. The operating lamp in the On / Off switch lights up.
3. Turn the thermostat control (7) clockwise until it resists to switch on the device. The
heating control lamp (8) lights up. The solution starts boiling.
4. As soon as the solution comes to a boil, turn the thermostat control counter clockwise
so that the heating control lamp goes out (see the "Preparation" chapter | "Interval
Boiling"). Let the solution take effect for a little while.
5. Allow the solution to run through the discharge tap (13) so that it is also freed of any
limescale residues (see the "Operation" chapter | "Operating the Discharge Tap").
6. To rinse the device, allow two tankfuls of clear water to run through it. The device is
now descaled and ready to be used again.
Storage
Disconnect the device from the mains power when it is not going to be used for a
prolonged period. Clean the device again (see the "Cleaning and Care" chapter) to avoid
possible mould formation. Mould can cause spots and damage on the device that can no
longer be removed / repaired. Allow the device and all accessories to dry completely.
Store the device and all accessories in a dry, clean, frost-free place that is protected from
direct sunlight and cannot be accessed by children or animals.
Troubleshooting
If the device does not work properly, check whether you are able to rectify the problem
yourself. If the problem cannot be solved with the steps that are listed, contact the cus-
tomer service department.
Do not attempt to repair a defective electrical device yourself!
Problem
The device cannot
be switched on.
Possible cause
The mains plug is not inserted
correctly in the socket.
The socket is defective.
No mains voltage is present.
The On / Off switch (12) has
not been activated.
The thermostat control (7) has
not been activated.
Fix
Insert the mains plug.
Try another socket.
Check the fuse of the mains
connection.
Move the On / Off switch to
position I.
Turn the thermostat control
clockwise until it resists.
34