Installation and operating manual
Turn the EMERGENCY stop button to the right until it releases:
The control unit is switched on.
Attach the load.
On wire ropes with hooks: Close the safety catch.
Always abide by the maximum permitted load when loading the load lifting equipment.
Note:
Moving / rocking whilst stopped can result in the "overload" buzzer being activated or the warning light coming on. No overload is
present if the buzzer or the warning light switches off as soon as the man riding equipment stops moving.
7.2

Operation of the hoist

Run the hoist in the pulling direction until the wire rope is tensioned (run hoists with two speeds at the lower speed).
Run the hoist in the pulling direction until the load lifting equipment is raised or pulled.
Let down or release load.
Observe the end of the rope when lowering or slackening.
Stop immediately when damage, loops or knots are detected.
Stop: Release the button.
If the wire rope / hoist does not stop:
Press the EMERGENCY stop button.
If the EMERGENCY stop button fails, disconnect the hoist power supply (e.g. by pulling out the plug).
Have the hoist inspected and serviced by an electrician or authorized service personnel (see '8.1 Trained and certified
maintenance personnel' on page 49).
7.2.1 Radio remote control
See Illustration 12.

Activating the remote control

Unlock the EMERGENCY stop button on the radio remote control (9).
Press the two buttons (7) and (8) on the remote control simultaneously until the green indicator light starts to flash.
The remote control is now switched on.
Button functions: see § 4.3.
Switching the radio remote control back on after having used the EMERGENCY stop button:
Unlock the EMERGENCY stop button on the radio remote control (9).
Press the two buttons (7) and (8) on the remote control simultaneously until the green indicator light starts to flash.
7.3

Measures following an emergency stop

First make sure that the power supply is not interrupted.
a) The phase sequence relay has triggered.
Turn the phase reverser in the CEE plug by 180° (see Illustration 22).
b) On hoists fitted with hand cranks: The hand crank is in the operating position.
In case the hand crank is not in operating position:
Have the hoist inspected and serviced by an electrician or authorized service personnel (see § 8.2).