Engine Power Correction Factors - Wacker Neuson G 100 Notice D'emploi

Groupe électrogène mobile
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation
4.17

Engine Power Correction Factors

Performance
Performance data on John Deere engines are measured at the following standard
data
conditions:
conditions
744 mm (29.31 in.) of mercury dry air pressure
183 m (600 ft.) altitude
0% relative humidity
25°C (77°F) air intake temperature
40°C (104°F) fuel inlet temperature
Refer to the table below to estimate the engine power decrease in percent as
environmental factors vary from the standard conditions.
Engine power
correction
factors
Model
G 100
G 120
Fuel temp
Air temp
rise of 1°C
rise of -12°C
(1.8°F)
(10°F)
None
0.50
(ECU
compensated)
50
G 100 / G 120
Altitude
Relative
rise of 305 m
humidity rise
(1000 ft)
of 10%
above 3050 m
(10,000 ft)
0.07
4.00
Altitude
rise of 305 m
(1000 ft)
below 3050 m
(10,000 ft)
0.5
wc_tx001687gb.fm

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

G 12006206490620650062065106206520620653 ... Afficher tout

Table des Matières