G 100 / G 120
4.16

Engine Monitoring

Description
With the engine start switch set to "RUN/START" or "REMOTE START", engine
information will be continuously displayed on the bottom line of the LCD panel.
Indicators
Symbol
wc_tx001687gb.fm
Meaning
Description
OIL
Displays engine oil pressure between 0–100 psi.
Normal operating pressure = 60–80 psi.
Engine shuts down automatically below 15 psi.
FUEL
Indicates relative fuel level in the fuel tank.
Engine shuts down automatically at 5% level.
TEMPERATURE
Displays temperature of engine coolant.
Engine shuts down automatically if coolant tem-
perature gets too high.
BATTERY
Measures engine starting battery voltage.
Normal reading is 13.5–14.5V.
Check engine charging system if voltage falls sig-
nificantly outside this range.
Actual battery voltage is displayed when the
engine switch is set to REMOTE START and the
generator is in standby mode.
Engine running hours are displayed on the hour
meter.
ENGINE HOURS
Engine hours accumulate only while engine is
actually running.