Engine Auto Idle

The auto idle switch automatically reduces engine speed approximately seven
seconds after all appliances or tools attached to the generator have been turned
off. The engine automatically returns to full speed when a tool or appliance is
turned back on.
To turn the auto idle feature on, push the auto idle switch to AUTO. The AUTO
setting is recommended while the generator is running to minimize fuel
consumption. To avoid extended engine warm-up periods, keep the auto idle
switch set to OFF when starting the engine and until the engine reaches operating
temperature.
Note: Not available on the GP2500.
4.20

Engine Speed

Generators require a fixed engine speed to maintain the correct voltage. Engine
speed is controlled by a governor which automatically adjusts to varying loads on
the engine to maintain a constant speed (see Technical Data). There is no throttle
control. Use the Auto Idle switch on the generator to control engine speed.
4.21
Voltage Selector—GP3800A, GP5600A, GP6600A
The voltage selector switch (a) allows the generator to operate in either single
(120V) or dual voltage (120/240V) mode.
In single-voltage mode, use only the 120V twist-lock (b) and the two duplex
receptacles (c). The full rated power of the generator is shared between the three
receptacles.
In dual voltage mode both the 120V and 120/240V receptacles are powered; lower
watts are available on receptacle (b) and receptacles (c). The
120/240V twist-lock receptacle (d) should be used in dual mode only. To achieve
full power in this receptacle, it should be used alone.
NOTICE: Never switch the voltage selector switch with the main breaker on! This
can cause arcing and can damage the generator. Turn all tools and appliances off
and place main breaker (e) in the OFF position before changing voltage switch
position.
wc_tx004573gb.fm
WARNING
TEST BEFORE EACH USE
SEE INSTRUCTIONS
d
TEST
P
F
O
A
W
U
E
L
R
T
RESET
GFCI
SENSING MODULE
a
e
b
39
Operation
c
wc_gr014713