Labels
h
j
GND
k
GP2500A
m
GP2500A
GP38 / 56 / 6600A
n
o
GFCI TEST INSTRUCTIONSTEST—BEFORE EACH USE
Normal operating state - sensing device green LED is ON and circuit breaker is at ON position.
1: Press TEST button. Green LED should go OUT, red LED should come ON, and circuit breaker
should trigger to OFF position.
2: If sensing device LED or breaker does not trip or change state, DO NOT USE. Consult an
electrician for assistance.
3: Press RESET button. Red LED should turn OFF and green LED should turn ON.
4: Manually reset (switch) circuit breaker to ON position to restore circuit power.