Starting—GP2500A
1. Ensure that the generator is properly installed in an outdoor location. See
Installation and Operator Safety while using Internal Combustion Engines for
installation warnings and safety guidelines.
2. Disconnect all loads from the generator.
3. Open the fuel valve (a1).
Note: If the engine is cold, move the choke lever to the closed position (b2). If the
engine is hot, set the choke to the open position (b1).
4. Turn the engine switch to ON (c1).
5. Pull the starter rope (d).
Note: If the oil level in the engine is low, the red LED at the engine switch will light
and the engine will not start. If this happens, check the oil level and add oil as
needed.
6. Open the choke as the engine warms (b1).
7. Allow the engine to warm up a few minutes before attaching loads.
a2
4.24
Stopping—GP2500A
1. Turn off and disconnect all tools and appliances attached to the generator.
2. Turn the engine switch to "OFF" (c2).
3. Close the fuel valve (a2).
Note: To stop the engine quickly in an emergency, turn the engine switch to "OFF"
(c2).