7.2.5 Connecting the Ethernet cable
(for IP board version only)
To connect the net cable a UTP, Category 5E or
superior, 4 pair with a max length of 100m. is needed.
j
Telemetry transmission and video signal
pass through the Ethernet cable. Do not
connect cable RS485 and the video cable.
Crimp the RJ45 connector on the ethernet cable.
Crimping should be straight-through if passing via
a hub or switch while it should be crossover if you
are connecting directly to the PC for the necessary
checks.
Connect the crimped net cable to connector RJ45
located on the base of the unit.
Fig. 32
The example below shows a typical installation.
Personal
Computer
Fig. 33
20
UTP cat 5E
Hub / Switch
UTP cat 5E

7.3 Fixing the top unit

Inside the bottom cover there is a sachet
j
containing desiccant that is used to prevent
moisture formation in the base and near
the connector boards. Remove the sachet
during installation.
Attach the top unit (01) to the base (02) using
the attachment screws (03), supplied with the
corresponding seals (04). Make sure the base seal is
present and in good condition (05).
h
Fasten with tightening
torque of 4Nm.
05
Fig. 34
There is only one way to anchor the base
j
with the top part. Align the tabs on the
sides to make sure the parts are positioned
correctly.
Fig. 35
01
02
04
03