8 Switching on

g
Make sure that the ULISSE system and other
components of the installation are closed
so that it is impossible to come into contact
with live parts.
i
Do not stay in the vicinity of the device
when it is powered. Always disconnect the
power supply before working on the device.
Make sure that all parts are fastened down
h
firmly and safely.
Systems in the ULISSE line are switched on by simply
connecting the power supply, and switched off by
disconnecting the power.
The automatic pre-heating (de-ice) process
j
could be started whenever the device is
switched on and the air temperature is
below 0°C. This process is used to ensure
that the device works properly even at low
temperatures; it lasts between 60 and 105
minutes depending on the model.
24

8.1 Before powering the device

The first time the device is switched on we
recommend making sure it is configured correctly.
To do this, disconnect the power supply, remove the
dip-switch protection window and set the firmware
update dip-switch rocker to ON.
Power the device and after a few seconds it will be
possible to check the settings on the screen.
After completing the check, switch off the device
and re-toggle the firmware update dip-switch rocker
to the down position (number 1 in the baud rate
section).
Close the window and re-connect the power supply.

8.2 Checks list

While it is switching on, the device displays a list of
the checks it has to carry out before starting normal
operation.
STARTUP
------------------------
TEST FLASH
HOMING PROCEDURE
ZFI SEARCH
IO EXPANDER
IR360 STATE
Fig. 43
If one of the checks fails (ERR), seek
h
assistance. The message Off means that the
pan & tilt is not fitted with the described
option.
: OK
: OK
: OK
:OFF
:OFF