Testing The Remote Monitoring Centre's Call Numbers; Programming The Test Cycle Call Frequency - diagral TT385 Guide De Pose

Transmetteur téléphonique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9.5
Testing the remote monitoring centre numbers
First of all let the remote monitoring centre know that you are going to do a test call.
Follow the operations below:
memory
n° (1, 2, 3, 4)
9.6
Programming the test call cycle frequency
The test call cycle makes it possible to automatically check that the telephone link between the dialler
and the remote monitoring centre is working. This test call can take place daily, every week, every
fortnight or every month.
If the dialler is connected to the DIAGRAL remote monitoring centre, the test call cycle must be pro-
grammed to occur daily.
The first test call automatically takes place 12 hours after the change to normal operating mode, i.e.
once the dialler has been fixed in place. All the following calls will take place at the same time.
Every time the dialler is switched to test mode the test call cycle time changes accordingly.
To choose the test call cycle frequency, follow the operations below:
1
9
3
0
: no test call cycle
: one test call cycle every day
1
: one test call cycle every week
2
: one test call cycle every fortnight
3
: one test call cycle every month
4
the red LED
lights up
Long BEEP: correct programming
30