The machine won't start
The batteries do not hold their charge
Display Alarms
Alarm
Battery terminals disconnected.
Batteries discharged.
Emergency stop button pressed.
Driver detection device faulty.
Operator not correctly seated.
Main fuse burned out.
Power control board fuse burned out.
Electrolyte low.
Battery terminal loose.
Error indicator
Brush Motor Cutout Tripped
Brake
Stand-by
Release Accelerator
Eeprom 1 Fault
Drive Control Board Cutout Tripped
Accelerator Fault
Max. Speed Potentiometer Fault
Undervoltage Fault
Overvoltage
Relay fault
HPD
MOSFET fault
EEPROM 2 fault
Service
Battery discharged
Check.
Recharge.
Reset.
Replace.
Sit correctly in the seat.
Replace.
Replace.
Top up.
Tighten.
What to do
The brush motor has overheated.
The parking brake is engaged or the
drive motor has overheated.
The driver detection microswitch is not
detecting an operator.
Incorrect starting sequence. Release the
accelerator pedal when starting.
Replace the display board.
The drive control board has overheated.
There is a problem with the accelerator
cable.
There is a fault in the maximum speed
potentiometer cabling.
Check the batteries.
Check the batteries.
Replace the drive control board.
Check the accelerator pedal. Switch
the machine off and back on with the
accelerator released.
Replace the drive control board.
Replace the drive control board.
Call a service centre to arrange servicing.
Battery discharged.