Wiring Accessories to the Expansion Board

Refer to the chart below and the corresponding image for a description of the expansion board inputs.
1
Wireless edge
2
Entrapment Protection Device
Inputs (4 terminals total), Open or
Close Direction based on switch
setting next to inputs
3
Single Button Control, SBC (2
terminals)
4
Open Input (& common) (3-Button
Control Station, 4 terminals total)
5
Close Input (& common) (3-Button
Control Station, 4 terminals total)
6
Stop Input (& common) (3-PB
station, 4 terminals total)
7
Exit Loop Input (2 terminals)
8
Shadow Loop Input (2 terminals)
9
Interrupt Loop Input (2 terminals)
8
7
9
EXPANSION BOARD
Connection for wireless edge receiver
EYES ONLY Input: Open or Close Direction Photoelectric Sensors, Close: reverses fully, Open: stops
gate/door
EYES/EDGE Input(s): Open or Close Direction Photoelectric Sensors, Infra-red detector wired or Edge
Sensor, Close: reverses fully, Open: stops gate/door
Gate command sequence - Open, Stop, Close, Stop, ... Soft Open ,Soft Close, Soft Stop (maintained
switch does not override external safeties and does not reset alarm condition)
Open command - opens a closed gate/door.
Soft open (maintained switch does not override external safeties and does not reset alarm condition) If
maintained, pauses Timer-to-Close at OPEN limit.
Opens a closing gate/door and holds open an open gate/door.
Close command - closes an open gate/door.
Soft close (maintained switch does not override external safeties and does not reset alarm condition).
Stop command - stops a moving gate/door.
Hard stop (maintained switch overrides Open and Close commands and resets alarm condition) If
maintained, pauses Timer-to-Close at OPEN limit.
Overrides an Open or Close command.
Loop wire connection for plug-in loop detector when loop is inside secured area near gate/door.
Open command - opens a closed gate/door.
Soft open (maintained switch does not override external safeties and does not reset alarm condition) If
maintained, pauses Timer-to-Close at OPEN limit.
Opens a closing gate/door and holds open an open gate/door.
Loop wire connection for plug-in loop detector when loop is positioned under the gate/door.
Holds open gate/door at open limit
l
Disregarded during gate/door motion
l
Pauses Timer-to-Close at Open Limit
l
Loop wire connection for plug-in loop detector when loop is along the side of the gate/door.
Holds open gate/door at open limit
l
Stops and reverses a closing gate/door
l
Pauses Timer-to-Close at Open Limit
l
32
1
Wireless edge
2
Photoelectric sensor
Photoelectric
sensor or edge
Photoelectric
sensor or edge
3
4
5
6