Diagnostic Codes Table - LiftMaster Elite Serie Manuel D'installation

Actionneur de porte et barrière basculantes commerciales 24 v c. c. pour trafic intense avec batterie de secours
Masquer les pouces Voir aussi pour Elite Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Diagnostic Codes Table

Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on the display as it occurs, then disappear.
LiftMaster System
Code
Meaning
31
Main control board has experienced an internal
failure.
34
Absolute Position Encoder Error, not getting
position information from encoder
35
Max-Run-Time Exceeded Error
36
Product ID Error
37
Product ID Failure
38
Hard Stop Limit
40
Battery overvoltage
41
Battery overcurrent
42
No battery at boot up
43
Exit Loop Error
44
Shadow Loop Error
45
Interrupt Loop Error
46
Wireless edge battery low
50
Door out of balance detected
53
Brownout occurred
Minimum number of monitored entrapment
60
protection devices not installed.
61
CLOSE EYE/INTERRUPT held more than 3 minutes
62
CLOSE EDGE held more than 3 minutes
63
OPEN EYE/EDGE held more than 3 minutes
64
CLOSE EYE/INTERRUPT held more than 3 minutes
65
CLOSE EYE/EDGE held more than 3 minutes
66
OPEN EYE/EDGE held more than 3 minutes
67
Wireless edge triggered more than 3 minutes
68
Wireless edge loss of monitoring
69
Wireless edge triggered
TROUBLESHOOTING
Installed System
Solution
Disconnect all power, wait 15 seconds, then reconnect power (reboot). If
issue continues, replace main control board.
Check APE assembly and wiring connections. Replace the APE assembly
if necessary.
Check for an obstruction, then reprogram the limits.
Was the control board just replaced? If so, erase limits, enter limit setup
mode and set limits. If not, disconnect all power, wait 15 seconds, then
reconnect power before changing product ID harness.
Unplug product ID harness then plug back in. Disconnect all power, wait
15 seconds, then reconnect power before replacing product ID harness.
Limit may be set too tightly against a non-resilient hard stop (re-adjust
limit). Operator may be at end of travel (re-adjust mounting).
Too much voltage on the battery. Check harness. Make sure there is NOT a
24V battery on a 12V system.
Possible short of the battery charge harness. Check harness. Make sure
you do NOT have a 12V battery on a 24V system.
Check battery connections and installation. Replace batteries if depleted to
less than 20V on a 24V system or less than 10V on a 12V system. Make
sure there is NOT a single 12V battery on a 24V system.
Failure or missing loop (SHORT or OPEN - LiftMaster Plug-in Loop
Detector only) Check loop wiring throughout connection. May be a short
in the loop, or an open connection in the loop.
Replace batteries in wireless edge.
Check counterbalance spring condition and setting.
AC/DC board supply dipped below allowable level. Review power supply
and wiring. If rebooting, ensure enough time for discharge of power to
force a fresh boot.
Review monitored entrapment protection device connections. Vertical
gate/door operators require the installation of the first external monitored
entrapment protection device in the close direction to function.
Check wired input on main control board; check for alignment or
obstruction.
Check wired input on expansion board; check for alignment or
obstruction.
Check wired input for wiring issue or obstruction.
Check wireless edge inputs.
IF an obstruction occurred, no action required. If an obstruction did NOT
occur, check inputs and wiring.
Informational
35
External Entrapment
Protection
Inherent Entrapment
Protection
Saved
NO
YES
YES
YES
YES
NO
YES
YES
YES
YES
YES
YES
YES
NO
YES
YES
YES
YES
NO