All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P,
CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings.
External Control Devices
EXIT (2 Terminals)
This input is a soft open command (maintained switch does not override
external safeties and does not reset alarm condition). Used for exit probe,
telephone entry, external exit loop detector, or any device that would
command the gate/door to open.
Opens a closing gate/door and holds open an open gate/door, if
l
maintained, pauses Timer-to-Close at OPEN limit.
SHADOW (2 Terminals)
This input is used for external shadow loop detector when loop is
positioned under the swing of the gate/door.
Holds open gate/door at open limit
l
Only active when the gate/door is at the OPEN limit, disregarded at all
l
other times
Pauses Timer-to-Close at OPEN limit
l
INTERRUPT (2 Terminals)
This input is used for photoelectric sensors and external interrupt loop
detector when loop is on the outside of the gate/door.
Holds open gate/door at open limit
l
Stops and reverses a closing gate/door to open limit
l
Pauses Timer-to-Close at OPEN limit, activates quick close and anti-
l
tailgate features when enabled on the expansion board
External Reset Button
The externally located reset button serves several functions:
Press the reset button to stop a moving gate/door during a normal
l
open/close cycle, like a stop button.
Press the reset button once while the gate/door is in open position to
l
disable the Timer-to-Close. The gate/door will stay in the open
position. To restart the Timer-to-Close either press the reset button
or activate the gate/door with a programmed remote control.
Press the reset button to shut off the alarm and reset the operator.
l
WIRING
STOP and COM: Stops a moving gate/door. Hard stop (maintained
l
switch overrides Open and Close commands and resets alarm
condition). Cancels/resets Timer-to-Close at OPEN limit. Overrides
Open and Close commands (within line-of-sight)
ACCESSORY WIRING
27
Control Board
Exit
Com
Shadow
Com
Interrupt
Com
Main Control Board
Stop
Com