To protect against fire and electrocution:
DISCONNECT power (AC or solar and battery) BEFORE installing or
l
servicing operator.
Two 12V Solar Panels in Series (Optional)
+
-
+
Input Power
Connection
Green
White
Black
Power Wiring Sockets
(120 Vac factory default)
EMI BOARD
WIRING DIAGRAM
Coaxial Antenna Cable
DIAGNOSTICS
-
Red
12V 7AH Battery
12V 7AH Battery
Black
Black
Red
Blocking Diode
Transformer 375 VA, 24V, 120V
Gray
Blue
Orange
Brown
Purple
Bridge Rectifier
Orange
Piggy Back
AC Power
Switch
Power Wiring Connector
For continued protection against fire:
Replace ONLY with fuse of same type and rating.
l
Antenna
CONTROL BOARD
Product ID
Reset Button
-
+
-
-
1/2 HP 24 Vdc Motor
Wire Loop
Wire Loop
Wire Loop
Field Wiring
41
External Reset
Button
Jumper
+
+
+
N.C.
-
Photoelectric Sensors
-
+
and Edge Sensors
-
+
-
+
-
+
-
+
-
+
Piezo Alarm
Black
APS Encoder
EXPANSION BOARD
N.C.
Jumper
Field Wiring
Wireless
Edge
Eye