Lenze ECS Série Instructions De Montage page 140

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4
Electrical installation
Wiring of the feedback system
Digital frequency input/output (encoder simulation)
2 to 3 slaves connected to the master:
ƒ
Use the EMF2132IB digital frequency distributor to wire the ECS axis
modules with master digital frequency cable EYD0017AxxxxW01W01 and
slave digital frequency cable EYD0017AxxxxW01S01.
PLC
X
S
Fig. 4−22
ECS axis modules in the digital frequency network with digital frequency distributor
EMF2132IB
PLC
E−Shaft
master
Slave 1...3
0
1
I
Tip!
"xxxx" in the type designation of the digital frequency cables
serves as a wildcard for the specification of the cable length in
decimetres.
Example: EYD0017A0015W01W01 ® cable length = 15 dm
140
E-Shaft Master
Slave 1
ECS
ECS
X4
X4
X14
X14
X8
X8
0
1
X5
Master control (PLC) or a PLC device to control the drive system
Master value master (axis module ECSxP)
Slave 1, slave 2, slave 3 (axis module ECSxP)
Master digital frequency cable EYD0017AxxxxW01W01 (socket/socket)
Slave digital frequency cable EYD0017AxxxxW01S01 (plug/socket)
l
Slave 2
ECS
X4
X14
X8
1
EMF2132IB
X1
X2 X3 X4
Slave 3
ECS
X4
X14
X8
1
ECSXP001