Lenze ECS Série Instructions De Montage page 116

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4
Electrical installation
Control terminals
Analog input
Analog input configuration
Use C0034 to set whether the input is to be used for a master voltage
ƒ
(±10 V) or a master current (+4 ... 20 mA or ±20 mA).
Set jumper bar X3 according to the setting in C0034:
ƒ
(
Stop!
Do not plug the jumper on the pins 3−4! The axis module cannot be
initialised like this.
Jumper bar X3
5
3
1
5
3
1
116
Setting
6
5−6 open
4
Jumper on 1−2: Parking
position
2
6
4
5−6 closed
2
l
Measuring range
C0034 = 0 (master voltage)
Level: −10 ... +10 V
l
l
Resolution: 5 mV (11 bits + sign)
Scaling: ±10 V º ±16384 º ±100 %
l
C0034 = 1 (master current)
Level: +4 ... +20 mA
l
Resolution: 20 mA (10 bits without
l
sign)
Scaling:
l
+4 mA º 0 º 0 %
+20 mA º 16384 º 100 %
C0034 = 2 (master current)
Level: −20 ... +20 mA
l
Resolution: 20 mA (10 bits + sign)
l
l
Scaling:
±20 mA º ±16384 º ±100 %
EDKCSEX064 DE/EN/FR 4.0