Lenze ECS Série Instructions De Montage page 105

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connection plan for mimimum wiring with external brake resistor
L1
L2
L3
N
F4
Off
On
K1
K1
Fig. 4−3
Interconnected power system with external brake resistor
"
K1
F1 ... F4
Z1
Rb
J
0
EDKCSEX064 DE/EN/FR 4.0
K1
F1...F3
Rb
ext
J
Z1
"
"
L3 PE
BR0
+UG
+UG
L1
L2
BR1
X21
ECSxE...
X6
...
J
(Rb
)
ext
HF−shield termination by large surface connection to functional earth (see
mounting instructions for shield mounting ECSZS000X0B)
Twisted cables
Mains contactor
Fuse
Mains choke / mains filter, optional
External brake resistor
ext
KTY thermal sensor of the motor
System cable for feedback
l
Electrical installation
Power terminals
PE
-UG
+UG +UG
-UG
-UG
PE
PE
X22
X23
ECSxS/P/M/A...
X25
X24
BD1 BD2
U V W PE
"
"
"
"
M
3~
J
2
+
+UG +UG
-UG
-UG
PE
PE
X23
ECSxS/P/M/A...
X25
X24
X7
BD1 BD2
U V W PE
0
"
"
"
"
6
M
R
3~
J
2
+
ECSXA012
4
X7
0
6
R
105

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ecses sérieEcsep sérieEcsem sérieEcsea série

Table des Matières