Télécharger Imprimer la page

Nuova Simonelli Master coffee 1 Manuel D'instructions page 39

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PROGRAM STANDARD CONFIGURATION
Master Coffee/Cappuccino
Coffee Dose Delivery:
1 Short Espresso 90 water counts
2 Short Espressos 130 water counts
(with single cycle)
2 Short Espressos 85 water counts
(with double cycle)
1 Long Espresso 110 water counts
2 Long Espressos 160 water counts
(with single cycle)
2 Long Espressos 95 water counts
(with double cycle)
Milk Delivery Time:
Cappuccino 12 seconds
White Coffee 12 seconds
Hot Milk
16 seconds
Hot Water Delivery Time:
8 seconds
N° of Continuous Delivery Cycles:
5 cycles
Coffee Grinding Time:
1 Short Espresso 3.2 seconds
2 Short Espressos 3.2 seconds
1 Long Espresso 3.2 seconds
2 Long Espressos 3.2 seconds
Milk Washing Time:
40 seconds
Discharge Time:
1 Short Espresso 5 seconds
2 Short Espressos 6 seconds
1 Long Espresso 6 seconds
2 Long Espressos 7 seconds
Auto Washing Time:
3 seconds
Double/Single Cycle:
Double Cycle
Choose Language:
English
Discharge Option: With drawer No. 35
LIST OF DISPLAY MESSAGES
- NOT ALLOWED: The functions are not
enabled. Insert the "U" key
- GROUP HEATING : The unit is being hea-
ted
- MACHINE READY : The machine is ready
for dose selection
- MANUAL STOP: The manual stop control
has been used before the programmed
dose has been effected
- DECAF. SELECTED: Decaffeinated coffee
delivery selected
- PROG. CONTINUE: Continues program in
function
- PROGRAM DOSES: Delivery dose pro-
gramming phase
- GRINDING TIME: Grinding times program-
ming phase
- DELIVERY COUNT: Display of dose coun-
ters selected
- DISCHARGE OPTION: Grounds dischar-
ge programming phase
- UNIT CLEANING: Unit cleaning and repo-
sitioning phase
- DRAWER FULL: Grounds drawer full pre-
alarm
- DISCHARGE DRAWER: The Machine is
locked because the grounds drawer is full
- DRAWER OPEN: The grounds drawer is
missing or badly positioned
- DOUBLE CYCLE: Double cycle selected
- DOOR OPEN: Front door open
MALFUNCTIONS LIST
CAUTION: GENERAL RISK.
It is strictly forbidden for the operator to
intervene on the machine in the event that
one of the following malfunctions occurs.
Always use a qualified technician.
- FLOWMETER ERROR: The control unit
has detected a malfunction in the flowmeter
- DELIVERY ERROR: The machine has
reached the delivery time limit of 2 minutes
- GROUP ERROR: The control unit has detec-
ted a malfunction in the mechanical unit
- REFILL ERROR: The machine has rea-
ched the maximum time of the automatic
boiler water filling
- MILK DOSE ERROR : The milk dose has
not been programmed
- DOSE NOT ALLOWED : The water dose
for the coffee has not been programmed
35

Publicité

loading