Tip Jack
Test Lead
Connection
to tester
Figure 4
Remove the J-44175-A Fuel Composition Tester
from it's storage case and set it on a stable level
surface, such as a work bench.
Insert the black DMM test lead probe into the
negative "-" jack at the end of the Fuel Composition
Tester's handle. Then insert the red DMM test lead
probe into the positive "+" jack at the end of the
tester's handle (see figure 4). Make sure the DMM
test probes remain in full contact with the jacks in
the tester's handle. "Needle-point" insulation-
piercing type probes will not stay connected into
the tester connector jacks.
Activate the J-39200 DMM by turning the dial
to Volts-AC (V~). Then activate the frequency
measurement feature by pressing the button
marked "Hz". The Fuel Tester's output signal is to
be read as an "AC Frequency."
The next step is to activate the Fuel Composition
Tester by pressing it's Power button. The green
fuel diagnostic LED should light up and remain lit
when the tester is powered up. If the green LED
is not lit when the tester is powered up with no
fuel sample in it, or if the yellow LED is lit, please
refer to the Troubleshooting section of this manual.
Notice: The tester will automatically shut off
after 10 minutes to extend battery life. If more
time is needed to complete testing, push the
Power button to turn the tester on again.