Steam Outlet; Getting Hot Water; Machine Stop; Dose Programming (Ellisse De - Te) - Bezzera ELLISSE PM Manuel D'instructions

Masquer les pouces Voir aussi pour ELLISSE PM:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

on the dose control board to supply coffee.
To change the dose programming, follow the
instructions described in the chapter 5.7 of this
booklet.
The machine is preset to supply coffee in "non-
stop mode":
1) Press the "non-stop mode" key to start the sup-
ply (Fig. 7 - C; pos. f).
2) Press again the "non-stop mode" key (Fig. 7
- C; pos. f) to stop the coffee supply.
CAUTION!
The machine is equipped with an automatic sa-
fety device that stops the nonstop
supply after deliverying three consecutive liters.

5.4 Steam Outlet

1) In order to avoid eddies in the boiler, let off
steam by turning the relevant knob (Fig 1; pos
3).
2) Insert the nozzle (Fig 1; pos 2) into the contai-
ner with the water to be heated.
3) Turn the steam knob (Fig 1; pos 3).
The outlet steam depends on the knob turning:
the more the knob is turned, the more the
steam is let off.
4) After the steam has been blown off, turn the
knob off, take out the container and clean
immediately the nozzle with a damp cloth in
order to remove residual heated water.

5.5 Getting Hot Water

ELLISSE PM
1) Place the water container under the dispenser
(Fig. 1; pos. 6).
2) Turn on the knob (Fig. 1; pos. 7a) to get the
required quantity of water.
ELLISSE DE
1) Place the water container under the dispenser
(Fig. 1; pos. 6).
2) Press the key (Fig. 7 - B; pos. e) to get the
required quantity of water.
ELLISSE TE
1) Place the water container under the dispenser
(Fig. 1; pos. 6).
2) Press the key (Fig. 7 - C; pos. e) to get the
required quantity of water.

5.6 Machine Stop

1) Turn off the water knob.
2) Set the switch (fig. 6) in position 0 and verify if
the green light is off.
3) Switch OFF the omnipolar switch.
5.7 Dose Programming
(Ellisse DE - TE)
To program each single dose (fig.7 - B/C; pos.
a - d) do as follows: keep the touch-pad (Fig. 7 -
B/C; pos. f) pressed of the group interested in the
dose programming till the relevant LED flashes.
Within 4 seconds, press the required dose (fig.7
- B/C; pos. a - d) and after the quantity has been
supplied press again the same touch-pad.
During the programming only the leds relating
to the touch-pad (Fig. 7 - B/C; pos. f) and the
pressed touch are left on.
To program another dose, repeat the same pro-
cedure; however, this time the led relating to the
dose previously programmed, will not light up,
but that doesn't prevent the machine from repro-
gramming the dose.
(For 1÷3 groups machines)
Programming the first group, you program au-
tomatically the other groups. This first group only,
allows to transmit the program-ming to the others
which can be programmed also individually.
(For 4 groups machines)
Programming the first group, you program au-
tomatically the second group. Programming the
third group, you program au-tomatically the
fourth group. Every group can be programmed
also individually.
25
ELLISSE
MOD.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ellisse teEllisse de

Table des Matières