6 - MAINTENANCE

For a proper working of the machine follow the
maintenance instructions given below.

6.1 Safety Rules

Do not wash the machine with water jets.
Disconnect the machine by positio-
ning the omnipolar lever switch to
OFF and turn off the water knob be-
fore carrying out maintenance and/
or cleaning operations.
In case of malfunctioning machine, do not carry
out any temporary repair and call immediately
the technical assistance service.
Should the power supply cable be damaged,
switch off immediately the machine, stop the wa-
ter supply and ask for the technical assistance
service. Do not replace it by yourselves.
Carry out the cleaning/maintenance when the
machine is cold, wearing preferably, protective
gloves.

6.2 Machine Cleaning

Clean the following pieces: steam nozzle and hot
water dispenser (every time they are used), filter
holder and filter, grills of warmer and drain tray.

6.3 Scheduled Inspections

Wash the group on a daily basis as follows: at-
tach the filter holder with the blind filter to the
group and press the coffee dispensing button se-
veral times (Fig. 7; pos. a).
N.B.: You can put special powder detergents for
coffee machines in the blind filter.
Inspect every 15 days the small basin placed un-
der the drain tray.
Clean the group gasket weekly with the proper
brush supplied together with the machine (Fig. 8).
For the machine equipped with deconcentrator,
follow the enclosed maintenance instructions.

6.4 Thermostat Reactivation

If the yellow light that usually indicates the
working of the boiler heating element doesn't
turn on at the machine start up or turns off during
the working, reactivate the safety thermostat by
pressing the proper button inside the machine.
The button (D) must be pressed by the suitable
hole under the machine near the support foot.
If the intervention doesn't allow the boiler resi-
stance light to turn on and/or the thermostat goes
on breaking off the resistance supply, ask for the
technical assistance service.
To ask for technical assistance, apply to area
agent.
6.5

Correct disposal of this product

(Waste Electrical & electronic equipment)
(Applicable in the European Union and other
European countries with separate collection sy-
stems)
This marking shown on the product or
its literature, indicates that it should not
be disposed with other household wa-
stes at the end of its working life. To pre-
vent possible harm to the environment or human
health from uncontrolled waste disposal, please
separate this from other types of wastes and re-
cycle it responsibly to promote the sustainable
reuse of material resources.
Household users should contact either the retailer
where they purchased this product, or their local
government office, for details of where and how
they can take this item for environmentally safe
recycling.
Business useres should contact their supplier and
check the terms and conditions of the purchase
contract. This product should not be mixed with
other commercial wastes for disposal.
27
ELLISSE
MOD.
(Fig. 09)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ellisse teEllisse de

Table des Matières