INSTRUCTIONS FOR INSTALLATION

Fitting the fire to an existing chimney

The fire can be fitted into an existing chimney providing
that the chimney / flue dimensions are 150 mm or more.
A special flue kit is required, which can be obtained from
Drugasar or a Drugasar agent. Do not use any other type
of flue system for this.
BS 5871 – 1 : 2001
Any chimney previously used for an appliance burning
a fuel other than gas shall be swept thoroughly before
installing any gas appliance.
Appliances shall be connected only to the types and sizes
of flue system as specified.
For any other information about this flue system please
contact Drugasar or Drugasar approved agent.

Baffle

To ensure that the appliance
works satisfactorily,
it will need to be adjusted
according to the
customer-specific pipe system.
The baffle is supplied separately
and should be fitted into the
heater as indicated in fig. 6.
Use the adjustment jig provided
(fig. 5) to adjust the baffle to
the right size. Once it has been
adjusted, fix the damper in place
with the socket-head screw.
1 - 7 metres
vertical + roof duct (*)
7 - 12 metres
vertical + roof duct (*)
1 m vertical + 90Û bend
+ wall duct
1 m vertical + 90Û bend
+ max 2 m horizontal
+ wall duct (**)
1,5 m vertical + 90Û bend
+ max 4 m horizontal
+ wall duct (**)
(*) NB: The maximum length of vertical pipe is 12 metres.
(**) NB: the maximum length of horizontal pipe must not be exceeded.
Fig. 4 illustrates how to calculate the total lengths of pipe.
38
31
43
38c-1075
fig. 5
Airflow regulator
G31
6 mm
G31
6 mm
G31
6 mm
G31
6 mm
G31
6 mm

Connecting the Gas Supply

An approved connecting tap with coupling should be
used in the supply hose (In Belgium this must be B.G.V.
approved). Furthermore:
• Expel all air from the supply pipes/hoses before coupling
to the appliance.
• Do not turn the coupling tap when connecting it to the
gas supply.
• Avoid any pressure on the control tap and pipes.
• Check that all connections are gastight.
Ignition wire
During production the ignition wire is rolled up, as it is
1000 mm long. After installation, insulate the spark plug
wire to avoid leaks or the ignition not working properly.
NB: To ensure the ignition works properly, the ignition
wire must come into as little contact as possible with
2
the metal parts of the heater and should therefore
not be wound round the gas or pilot-light pipes or the
Distance
baffle
(fig. 6)
31 mm
31 mm
OPEN
OPEN
OPEN
26
Baffle
fig. 6
thermocouple.