Wall duct with concentric pipes

You must consider that for a wall duct, the first 0,5 or 1
metre of pipe must be fitted vertically. 0,5 metre for a
maximum of 2 metres horizontal pipe, and 1 metre for a
maximum of 3 metres of horizontal pipe.
• Determine the position of the appliance and the position
of the wall duct.
• Drill a Ø160 mm hole at the point where the wall duct is
required.Through flammable material Ø 230 mm.
• Now vertically connect one or more concentric pipes to
the heater outlet. Press well and fit the strip(s) of clip
binding.
• Place the bend on top of this, fit any horizontal concentric
pipes required, and make sure the connections are
gastight.
• Connect the wall duct to the bend or the horizontal pipes
and make sure that this connection is also gastight.

Roof duct with concentric pipes

A duct through a roof can open out anywhere on the roof,
with an extension to the ridge if necessary. Depending on
which of the aforementioned options has been chosen, the
roof duct will be supplied with either adhesive flashing for
a flat roof or a universally adjustable tile for a slanted roof.
• Determine the position of the appliance and the position
of the chimney.
• Drill a Ø 160 mm hole at the point where the chimney
is required.Through flammable material Ø 230 mm.
• Now vertically connect the concentric pipes to the
heater outlet. Press well and apply the clip binding.
• Determine the length of the pipes required and ensure
that the adhesive flashing or the universal tile fit properly.
• Saw the outside pipe off at the length required.
• Connect the roof duct to the concentric pipes.
NB: Alternatively, you can fit the concentric pipes before
installing the heater. In that case the connection to the
outlet of the appliance should be made using a length of
pipe that can be shortened later.

Fitting the fire to an existing chimney

The fire can be fitted into an existing chimney providing
that the chimney / flue dimensions are 150 mm or more.
A special flue kit is required, which can be obtained from
Drugasar or a Drugasar agent. Do not use any other type
of flue system for this.
BS 5871 – 1 : 2001
Any chimney previously used for an appliance burning a
fuel other than gas shall be swept thoroughly before
installing any gas appliance.
Appliances shall be connected only to the types and sizes
of flue system as specified.
For any other information about this flue system please
contact Drugasar or Drugasar approved agent.
INSTRUCTIONS FOR INSTALLATION
Baffle, fig. 12 (1)/Baffle plate, fig. 13 (3)
To ensure that the appliance works satisfactorily, it will
need to be adjusted according to the customer-specific
pipe system.
The baffle and the baffle plate are
supplied separately and should be fit-
ted into the heater as indicated in fig.
12 and fig. 13. Use the adjustment jig
provided (fig. 11) to adjust the baffle
to the right size. Once it has been
adjusted, fix the damper in place with
the socket-head screw.
Baffle plate: a baffle plate (5) should
be fitted if necessary.This is fitted to
the vermiculite tray (3) with four self-
tapping screws (4). Use the two slot-
ted holes and the 3rd and 18th holes
as shown in fig. 13. Before fitting the
baffle plate, bend it in two places to
form a right angle, as illustrated.
Make sure the square fold of the baffle
plate is straight under the edge of the
vermiculite tray (= dimension 0)
Replace the vermiculite tray and baffle
plate.
G25/G20
1 - 5m.
vertical + roof duct (*)
5 -12 m.
vertical + roof duct (*)
0,5 m vertical
+ 90º bend
+ wall duct
0,5 m vertical + 90º bend
+ max 2 m horizontal
+ muurdoorvoer (**)
1 m vertical
+ 90º bend
+ wall duct
1 m vertical + 90º bend
+ max 1m horizontal
+ wall duct (**)
1 m vertical + 90º bend
+ max 3 m horizontal
+ wall duct (**)
(*) NB:The maximum length of vertical pipe is
12 metres.
(**) NB: the maximum length of horizontal pipe must
not be exceeded.
Fig. 10 illustrates how to calculate the total lengths of pipe.
27
40
32
38c-1149
50
58
fig. 11
Baffle plate
Baffle
YES
YES
40 mm
YES
YES
32 mm
NO
YES
58 mm
NO
NO
OPEN
NO
YES
50 mm
NO
YES
58 mm
NO
NO
OPEN
Paco
Distance
baffle