General Notes; Gas Safety Regulations (For Installation & Use) 1998; Cleaning And Maintenance; Discoloration Of Walls And Ceiling - Dru Paco Instructions D'installation Et Mode D'emploi

Cheminée encastrable
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATING INSTRUCTIONS
Changing the code
The remote control code can be changed if so required.
This will require changing the DIP SWITCH, which is on
the remote control near the battery. Once the code has
been changed, press the reset button
on the receiver until you hear two sig-
nals. After the second, longer signal
release the reset button and within 20
seconds press
on the remote con-
trol until you hear an extra long signal.
This means that the new code has
been confirmed.

GENERAL NOTES

Gas Safety Regulations (for installation & use) 1998
In your own interest and that of safety, it is law that all gas
appliances are installed by competent persons in accor-
dance with the above regulations. Failure to install appli-
ances correctly could lead to prosecution.
NB: The Council of Registered Gas Installers,
whose members are identified by the emblem
shown here, are all required to work to the recog-
nised standards.

Cleaning and Maintenance

The appliance should be inspected once a year by a qualified
company, and cleaned and/or repaired as necessary.The
inspection and maintenance must at least ensure that the
appliance is working correctly and safely.This can be done
by your own gasinstaller or a specialised maintenance com-
pany. It is advisable to remove any dust from the appliance
several times before and during the heating season. After a
while a deposit will form on the inside of the glass pane.
This can be removed with a damp cloth or with a non-abra-
sive cleaning agent (e.g. brass polish). Do this as soon as any
deposit appears, to prevent it from burning and becoming
impossible to clean. Do not use corrosive or abrasive sub-
stances to clean the casing. Any damage to the coating,
caused by things put on or against the casing for example, is
not covered by the guarantee.
NB: When replacing the thermocouple, the coupling nut in
the gas control block should first be tightened by hand and
then tightened a quarter-turn with an open-ended spanner.
To be able to service the pilot light, the flap (x) can be
removed by unscrewing the 6 self-tapping screws (y), see
fig. 2.

Discoloration of walls and ceiling

Brown discoloration is an annoying problem, which is diffi-
cult to solve. It can be caused by dust burning as a result
of poor ventilation, for example, or by cigarette smoke or
candles.
These problems can be avoided by ensuring that the room
the heater is in is properly ventilated. A good guideline for
ventilation is:
New buildings
Existing buildings
Use candles and oil lamps as little as possible, keeping the
wick as short as possible.While they Enhance the atmos-
phere, candles and oil lamps also cause the formation of
large quantities of unhealthy soot particles in your home.
Cigarette and cigar smoke contains tar, which upon heating
will precipitate on cold or damp walls. If you have a newly
cemented chimney or have had any other reconstructions
/ renovations done, you are advised to wait at least 6
weeks before lighting your fire, to allow the walls, floor
and ceiling to dry out completely.

Lighting the heater for the first time

There can be an unpleasant smell when you light the
heater for the first time.This is caused by the varnish
evaporating and will disappear after a few hours.We there-
fore advise you, on initial use, to heat the appliance at the
highest setting while ventilating the room it is installed in
well.

Extra protection

This heater meets the normal safety standards regarding
surface temperatures, but physical contact with heated
surfaces should be avoided where possible. An additional
guard is recommended to protect young children and eld-
erly, infirmed or handicapped people. For safety reasons a
guard should be placed in front of the fire at all times.

Disposal

When replacing or otherwise removing the appliance, it
should be disposed of in compliance with current regula-
tions.
Shut off the connecting tap with coupling before com-
mencing disassembly. Undo the coupling between the con-
necting tap and the appliance.The whole appliance can
now be disassembled and removed.
33
GENERAL NOTES
: 3.24 m 3 / hour per m 2 floor
surface of the room.
: 25.20 m 3 / hour for a room.
Paco

Publicité